The fire-rated main door stops about 10 cm short of closing by itself.
Location: Main entrance door
Recommendation: Developer to rectify before handover (doors and ironmongery). (Doors and ironmongery)
Dubai
Numbers match the findings below.
The apartment is generally well finished, with 22 snags for the developer before handover. Three are safety items: a loose balcony glass clamp, a bedroom window that does not lock and a painted-over smoke detector. Most other items are finishing and MEP fixes.
Top concerns
Safety
The fire-rated main door stops about 10 cm short of closing by itself.
Location: Main entrance door
Recommendation: Developer to rectify before handover (doors and ironmongery). (Doors and ironmongery)
Four tiles sound hollow when tapped, a sign the adhesive bed is incomplete. Hollow tiles can crack under load.
Location: Living room, by balcony door
Recommendation: Developer to rectify before handover (tiling). (Tiling)
Visible roller marks and two filled patches on the long wall that show under side light.
Location: Living room, long wall
Recommendation: Developer to rectify before handover (painting). (Painting)
Daylight is visible along the bottom of the balcony sliding door when closed; dust and water can get in.
Location: Balcony sliding door
Recommendation: Developer to rectify before handover (aluminium and glazing). (Aluminium and glazing)
The supply grille sits about 5 mm proud of the gypsum ceiling on one side.
Location: Living room ceiling
Recommendation: Developer to rectify before handover (mep / hvac). (MEP / HVAC)
The joint between the two countertop sections is open by about 2 mm and not sealed.
Location: Kitchen counter
Recommendation: Developer to rectify before handover (joinery). (Joinery)
Water drips from the waste connection under the sink when the tap runs for a minute.
Location: Under kitchen sink
Recommendation: Developer to rectify before handover (plumbing). (Plumbing)
The hood runs but there is no airflow at the outlet; the duct may not be connected.
Location: Above the hob
Recommendation: Developer to rectify before handover (mep / hvac). (MEP / HVAC)
A 60 cm hairline crack runs along a board joint in the master bedroom ceiling.
Location: Master bedroom ceiling
Recommendation: Developer to rectify before handover (gypsum and ceilings). (Gypsum and ceilings)
The right wardrobe door rubs the frame and does not close flush.
Location: Bedroom 2 wardrobe
Recommendation: Developer to rectify before handover (joinery). (Joinery)
The window handle turns but the lock does not engage; a child could open it.
Location: Bedroom 2 window
Recommendation: Developer to rectify before handover (aluminium and glazing). (Aluminium and glazing)
The fan-coil unit above the master bedroom rattles at medium and high speed.
Location: Master bedroom
Recommendation: Developer to rectify before handover (mep / hvac). (MEP / HVAC)
The double socket by the bed moves in the wall when a plug is pushed in.
Location: Bedroom 2, bed wall
Recommendation: Developer to rectify before handover (electrical). (Electrical)
After a water test, water collects in the corner opposite the drain instead of running to it.
Location: Master bath
Recommendation: Developer to rectify before handover (tiling). (Tiling)
Several grout lines behind the basin are open, which lets water behind the tiles.
Location: Bath 2, basin wall
Recommendation: Developer to rectify before handover (tiling). (Tiling)
The WC pan rocks when sat on; the fixing bolts are not tight.
Location: Bath 2
Recommendation: Developer to rectify before handover (plumbing). (Plumbing)
There is no silicone seal along the bottom of the shower glass; water reaches the floor outside.
Location: Master bath shower
Recommendation: Developer to rectify before handover (tiling). (Tiling)
The fan does not start from the switch or the light circuit.
Location: Master bath ceiling
Recommendation: Developer to rectify before handover (mep / hvac). (MEP / HVAC)
One clamp on the balcony glass moves by hand and the panel flexes when pushed.
Location: Balcony, middle panel
Recommendation: Developer to rectify before handover (aluminium and glazing). (Aluminium and glazing)
Construction debris blocks the balcony floor drain; water would pond after rain or cleaning.
Location: Balcony drain
Recommendation: Developer to rectify before handover (civil works). (Civil works)
The room has no working extract fan or vent; the fan switch does nothing.
Location: Maid's room
Recommendation: Developer to rectify before handover (mep / hvac). (MEP / HVAC)
The detector in the entrance hall has paint over its vents, which can stop it sensing smoke.
Location: Entrance hall ceiling
Recommendation: Developer to rectify before handover (mep / fire). (MEP / fire)